Full description
Operation
Use the factory settings supplied with the unit. Consult the manufacturer before changing operating conditions, as changes can affect performance and treatment efficiency.
Operation steps
- Connect the power supply.
- Press START.
- Allow the automatic cycle to run.
- Run the odour-removal / sterilization operation.
- Stop the unit or place it on standby.
Installation steps
- Secure a level installation position near, and above, the coolant tank.
- Connect the PVC hose to the lower plasma discharge pipe and mixing tube (injection nozzle), and check all final connections.
- Place the connected mixing tube below the coolant surface in the tank.
- Connect the power, switch ON, press START and check normal RUN operation.
Safety precautions
- Do not disassemble or modify the unit: risk of fire, electric shock or failure.
- Do not use it for purposes other than coolant sterilization: risk of damage or accidents.
- Do not operate with wet hands: risk of electric shock.
- Disconnect the power before inspection: risk of electric shock or injury.
- Provide ventilation and keep the installation away from flammable materials.
- Drain the internal piping before prolonged non-use to help prevent freezing, corrosion and failure.
Applications
The source lists water-soluble cutting fluids, grinding fluids, large machine-tool coolant tanks and washing water in industrial cleaning equipment.