Full description
The source describes corona-discharge collection of fine airborne oil mist in factories and a reduction in microbial activity and odour through reactive species generated during discharge. The microbiological and odour-performance wording requires technical confirmation.
Ionization
In the ionising stage, high voltage applied to the discharge electrode produces Corona Discharge and charges airborne particles. Electrons and ions multiply through a chain reaction described in the source as Avalanche Multiplication.
Particle collection
Charged particles move towards the collection stage under electrical forces and accumulate on the collection plates.
Components
Components: IONIZER and CELL.
Specification conditions
- The specifications are based on 60Hz. Airflow decreases by approximately 20% at 50Hz.